summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorsongyanchao <[email protected]>2021-09-27 17:03:58 +0800
committersongyanchao <[email protected]>2021-09-27 17:03:58 +0800
commit416acc4b09da8da9df9e7f6f74a5c23ba8f923ba (patch)
treed6fd709d63de8bea9183c91b5ee2485969d2cefe
parent5116f5c2cac4036721903c1b65ddbfef8d36ded5 (diff)
✨ feat(NEZHA): Add NeZha Model
Add NeZha Config Model
-rw-r--r--NEZHA/.DS_Storebin0 -> 6148 bytes
-rw-r--r--NEZHA/config_file/AlertRule.xlsxbin0 -> 10043 bytes
-rw-r--r--NEZHA/config_file/IF-MIB.txt1895
-rw-r--r--NEZHA/config_file/SNMPv2-MIB.txt854
-rw-r--r--NEZHA/config_file/asset-model.xlsxbin0 -> 4373 bytes
-rw-r--r--NEZHA/config_file/chart-temp.xlsxbin0 -> 34078 bytes
-rw-r--r--NEZHA/config_file/module.xlsxbin0 -> 5222 bytes
7 files changed, 2749 insertions, 0 deletions
diff --git a/NEZHA/.DS_Store b/NEZHA/.DS_Store
new file mode 100644
index 0000000..1e89833
--- /dev/null
+++ b/NEZHA/.DS_Store
Binary files differ
diff --git a/NEZHA/config_file/AlertRule.xlsx b/NEZHA/config_file/AlertRule.xlsx
new file mode 100644
index 0000000..dc22341
--- /dev/null
+++ b/NEZHA/config_file/AlertRule.xlsx
Binary files differ
diff --git a/NEZHA/config_file/IF-MIB.txt b/NEZHA/config_file/IF-MIB.txt
new file mode 100644
index 0000000..a9372ab
--- /dev/null
+++ b/NEZHA/config_file/IF-MIB.txt
@@ -0,0 +1,1895 @@
+IF-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Counter64,
+ Integer32, TimeTicks, mib-2,
+ NOTIFICATION-TYPE FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString,
+ PhysAddress, TruthValue, RowStatus,
+ TimeStamp, AutonomousType, TestAndIncr FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP,
+ NOTIFICATION-GROUP FROM SNMPv2-CONF
+ snmpTraps FROM SNMPv2-MIB
+ IANAifType FROM IANAifType-MIB;
+
+ifMIB MODULE-IDENTITY
+ LAST-UPDATED "200006140000Z"
+ ORGANIZATION "IETF Interfaces MIB Working Group"
+ CONTACT-INFO
+ " Keith McCloghrie
+ Cisco Systems, Inc.
+ 170 West Tasman Drive
+ San Jose, CA 95134-1706
+ US
+
+ 408-526-5260
+ DESCRIPTION
+ "The MIB module to describe generic objects for network
+ interface sub-layers. This MIB is an updated version of
+ MIB-II's ifTable, and incorporates the extensions defined in
+ RFC 1229."
+
+ REVISION "200006140000Z"
+ DESCRIPTION
+ "Clarifications agreed upon by the Interfaces MIB WG, and
+ published as RFC 2863."
+ REVISION "199602282155Z"
+ DESCRIPTION
+ "Revisions made by the Interfaces MIB WG, and published in
+ RFC 2233."
+ REVISION "199311082155Z"
+ DESCRIPTION
+ "Initial revision, published as part of RFC 1573."
+ ::= { mib-2 31 }
+
+ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }
+
+interfaces OBJECT IDENTIFIER ::= { mib-2 2 }
+
+--
+-- Textual Conventions
+--
+
+-- OwnerString has the same semantics as used in RFC 1271
+
+OwnerString ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "255a"
+ STATUS deprecated
+ DESCRIPTION
+ "This data type is used to model an administratively
+ assigned name of the owner of a resource. This information
+ is taken from the NVT ASCII character set. It is suggested
+ that this name contain one or more of the following: ASCII
+ form of the manager station's transport address, management
+ station name (e.g., domain name), network management
+ personnel's name, location, or phone number. In some cases
+ the agent itself will be the owner of an entry. In these
+ cases, this string shall be set to a string starting with
+ 'agent'."
+ SYNTAX OCTET STRING (SIZE(0..255))
+
+-- InterfaceIndex contains the semantics of ifIndex and should be used
+-- for any objects defined in other MIB modules that need these semantics.
+
+InterfaceIndex ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each interface or
+ interface sub-layer in the managed system. It is
+ recommended that values are assigned contiguously starting
+ from 1. The value for each interface sub-layer must remain
+ constant at least from one re-initialization of the entity's
+ network management system to the next re-initialization."
+ SYNTAX Integer32 (1..2147483647)
+
+InterfaceIndexOrZero ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "This textual convention is an extension of the
+ InterfaceIndex convention. The latter defines a greater
+ than zero value used to identify an interface or interface
+ sub-layer in the managed system. This extension permits the
+ additional value of zero. the value zero is object-specific
+ and must therefore be defined as part of the description of
+ any object which uses this syntax. Examples of the usage of
+ zero might include situations where interface was unknown,
+ or when none or all interfaces need to be referenced."
+ SYNTAX Integer32 (0..2147483647)
+
+ifNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of network interfaces (regardless of their
+ current state) present on this system."
+ ::= { interfaces 1 }
+
+ifTableLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time of the last creation or
+ deletion of an entry in the ifTable. If the number of
+ entries has been unchanged since the last re-initialization
+ of the local network management subsystem, then this object
+ contains a zero value."
+ ::= { ifMIBObjects 5 }
+
+-- the Interfaces table
+
+-- The Interfaces table contains information on the entity's
+
+-- interfaces. Each sub-layer below the internetwork-layer
+-- of a network interface is considered to be an interface.
+
+ifTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of interface entries. The number of entries is
+ given by the value of ifNumber."
+ ::= { interfaces 2 }
+
+ifEntry OBJECT-TYPE
+ SYNTAX IfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing management information applicable to a
+ particular interface."
+ INDEX { ifIndex }
+ ::= { ifTable 1 }
+
+IfEntry ::=
+ SEQUENCE {
+ ifIndex InterfaceIndex,
+ ifDescr DisplayString,
+ ifType IANAifType,
+ ifMtu Integer32,
+ ifSpeed Gauge32,
+ ifPhysAddress PhysAddress,
+ ifAdminStatus INTEGER,
+ ifOperStatus INTEGER,
+ ifLastChange TimeTicks,
+ ifInOctets Counter32,
+ ifInUcastPkts Counter32,
+ ifInNUcastPkts Counter32, -- deprecated
+ ifInDiscards Counter32,
+ ifInErrors Counter32,
+ ifInUnknownProtos Counter32,
+ ifOutOctets Counter32,
+ ifOutUcastPkts Counter32,
+ ifOutNUcastPkts Counter32, -- deprecated
+ ifOutDiscards Counter32,
+ ifOutErrors Counter32,
+ ifOutQLen Gauge32, -- deprecated
+ ifSpecific OBJECT IDENTIFIER, -- deprecated
+ ifInPps Counter64,
+ ifInbps Counter64,
+ ifOutPps Counter64,
+ ifOutbps Counter64,
+ descript DisplayString,
+ wavelength Counter32,
+ vendor DisplayString,
+ rxpwr DisplayString,
+ txpwr DisplayString
+ }
+
+ifIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each interface. It
+ is recommended that values are assigned contiguously
+ starting from 1. The value for each interface sub-layer
+ must remain constant at least from one re-initialization of
+ the entity's network management system to the next re-
+ initialization."
+ ::= { ifEntry 1 }
+
+ifDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual string containing information about the
+ interface. This string should include the name of the
+ manufacturer, the product name and the version of the
+ interface hardware/software."
+ ::= { ifEntry 2 }
+
+ifType OBJECT-TYPE
+ SYNTAX IANAifType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of interface. Additional values for ifType are
+ assigned by the Internet Assigned Numbers Authority (IANA),
+ through updating the syntax of the IANAifType textual
+ convention."
+ ::= { ifEntry 3 }
+
+ifMtu OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The size of the largest packet which can be sent/received
+ on the interface, specified in octets. For interfaces that
+ are used for transmitting network datagrams, this is the
+ size of the largest network datagram that can be sent on the
+ interface."
+ ::= { ifEntry 4 }
+
+ifSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's current bandwidth in bits
+ per second. For interfaces which do not vary in bandwidth
+ or for those where no accurate estimation can be made, this
+ object should contain the nominal bandwidth. If the
+ bandwidth of the interface is greater than the maximum value
+ reportable by this object then this object should report its
+ maximum value (4,294,967,295) and ifHighSpeed must be used
+ to report the interace's speed. For a sub-layer which has
+ no concept of bandwidth, this object should be zero."
+ ::= { ifEntry 5 }
+
+ifPhysAddress OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interface's address at its protocol sub-layer. For
+ example, for an 802.x interface, this object normally
+ contains a MAC address. The interface's media-specific MIB
+ must define the bit and byte ordering and the format of the
+ value of this object. For interfaces which do not have such
+ an address (e.g., a serial line), this object should contain
+ an octet string of zero length."
+ ::= { ifEntry 6 }
+
+ifAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The desired state of the interface. The testing(3) state
+ indicates that no operational packets can be passed. When a
+ managed system initializes, all interfaces start with
+ ifAdminStatus in the down(2) state. As a result of either
+ explicit management action or per configuration information
+ retained by the managed system, ifAdminStatus is then
+ changed to either the up(1) or testing(3) states (or remains
+ in the down(2) state)."
+ ::= { ifEntry 7 }
+
+ifOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3), -- in some test mode
+ unknown(4), -- status can not be determined
+ -- for some reason.
+ dormant(5),
+ notPresent(6), -- some component is missing
+ lowerLayerDown(7) -- down due to state of
+ -- lower-layer interface(s)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operational state of the interface. The
+ testing(3) state indicates that no operational packets can
+ be passed. If ifAdminStatus is down(2) then ifOperStatus
+ should be down(2). If ifAdminStatus is changed to up(1)
+ then ifOperStatus should change to up(1) if the interface is
+ ready to transmit and receive network traffic; it should
+ change to dormant(5) if the interface is waiting for
+ external actions (such as a serial line waiting for an
+ incoming connection); it should remain in the down(2) state
+ if and only if there is a fault that prevents it from going
+ to the up(1) state; it should remain in the notPresent(6)
+ state if the interface has missing (typically, hardware)
+ components."
+ ::= { ifEntry 8 }
+
+ifLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time the interface entered
+ its current operational state. If the current state was
+ entered prior to the last re-initialization of the local
+ network management subsystem, then this object contains a
+ zero value."
+ ::= { ifEntry 9 }
+
+ifInOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received on the interface,
+ including framing characters.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 10 }
+
+ifInUcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were not addressed to a multicast
+ or broadcast address at this sub-layer.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 11 }
+
+ifInNUcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were addressed to a multicast or
+ broadcast address at this sub-layer.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime.
+
+ This object is deprecated in favour of ifInMulticastPkts and
+ ifInBroadcastPkts."
+ ::= { ifEntry 12 }
+
+ifInDiscards OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of inbound packets which were chosen to be
+ discarded even though no errors had been detected to prevent
+
+ their being deliverable to a higher-layer protocol. One
+ possible reason for discarding such a packet could be to
+ free up buffer space.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 13 }
+
+ifInErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For packet-oriented interfaces, the number of inbound
+ packets that contained errors preventing them from being
+ deliverable to a higher-layer protocol. For character-
+ oriented or fixed-length interfaces, the number of inbound
+ transmission units that contained errors preventing them
+ from being deliverable to a higher-layer protocol.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 14 }
+
+ifInUnknownProtos OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For packet-oriented interfaces, the number of packets
+ received via the interface which were discarded because of
+ an unknown or unsupported protocol. For character-oriented
+ or fixed-length interfaces that support protocol
+ multiplexing the number of transmission units received via
+ the interface which were discarded because of an unknown or
+ unsupported protocol. For any interface that does not
+ support protocol multiplexing, this counter will always be
+ 0.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 15 }
+
+ifOutOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets transmitted out of the
+ interface, including framing characters.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 16 }
+
+ifOutUcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were not addressed to a
+ multicast or broadcast address at this sub-layer, including
+ those that were discarded or not sent.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 17 }
+
+ifOutNUcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were addressed to a
+ multicast or broadcast address at this sub-layer, including
+ those that were discarded or not sent.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime.
+
+ This object is deprecated in favour of ifOutMulticastPkts
+ and ifOutBroadcastPkts."
+ ::= { ifEntry 18 }
+
+ifOutDiscards OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outbound packets which were chosen to be
+ discarded even though no errors had been detected to prevent
+ their being transmitted. One possible reason for discarding
+ such a packet could be to free up buffer space.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 19 }
+
+ifOutErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For packet-oriented interfaces, the number of outbound
+ packets that could not be transmitted because of errors.
+ For character-oriented or fixed-length interfaces, the
+ number of outbound transmission units that could not be
+ transmitted because of errors.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifEntry 20 }
+
+ifOutQLen OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The length of the output packet queue (in packets)."
+ ::= { ifEntry 21 }
+
+ifSpecific OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "A reference to MIB definitions specific to the particular
+ media being used to realize the interface. It is
+
+ recommended that this value point to an instance of a MIB
+ object in the media-specific MIB, i.e., that this object
+ have the semantics associated with the InstancePointer
+ textual convention defined in RFC 2579. In fact, it is
+ recommended that the media-specific MIB specify what value
+ ifSpecific should/can take for values of ifType. If no MIB
+ definitions specific to the particular media are available,
+ the value should be set to the OBJECT IDENTIFIER { 0 0 }."
+ ::= { ifEntry 22 }
+
+ifInPps OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "ifInPps"
+ ::= { ifEntry 23 }
+
+ifInbps OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "ifInbps"
+ ::= { ifEntry 24 }
+
+ifOutPps OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "ifOutPps"
+ ::= { ifEntry 25 }
+
+ifOutbps OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "ifOutbps"
+ ::= { ifEntry 26 }
+
+descript OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "descript"
+ ::= { ifEntry 27 }
+
+wavelength OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "wavelength"
+ ::= { ifEntry 28 }
+
+vendor OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "vendor"
+ ::= { ifEntry 29 }
+
+rxpwr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "rx-power"
+ ::= { ifEntry 30 }
+
+txpwr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "tx power"
+ ::= { ifEntry 31 }
+
+--
+-- Extension to the interface table
+--
+-- This table replaces the ifExtnsTable table.
+--
+
+ifXTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfXEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of interface entries. The number of entries is
+ given by the value of ifNumber. This table contains
+ additional objects for the interface table."
+ ::= { ifMIBObjects 1 }
+
+ifXEntry OBJECT-TYPE
+ SYNTAX IfXEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing additional management information
+ applicable to a particular interface."
+ AUGMENTS { ifEntry }
+ ::= { ifXTable 1 }
+
+IfXEntry ::=
+ SEQUENCE {
+ ifName DisplayString,
+ ifInMulticastPkts Counter32,
+ ifInBroadcastPkts Counter32,
+ ifOutMulticastPkts Counter32,
+ ifOutBroadcastPkts Counter32,
+ ifHCInOctets Counter64,
+ ifHCInUcastPkts Counter64,
+ ifHCInMulticastPkts Counter64,
+ ifHCInBroadcastPkts Counter64,
+ ifHCOutOctets Counter64,
+ ifHCOutUcastPkts Counter64,
+ ifHCOutMulticastPkts Counter64,
+ ifHCOutBroadcastPkts Counter64,
+ ifLinkUpDownTrapEnable INTEGER,
+ ifHighSpeed Gauge32,
+ ifPromiscuousMode TruthValue,
+ ifConnectorPresent TruthValue,
+ ifAlias DisplayString,
+ ifCounterDiscontinuityTime TimeStamp
+ }
+
+ifName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The textual name of the interface. The value of this
+ object should be the name of the interface as assigned by
+ the local device and should be suitable for use in commands
+ entered at the device's `console'. This might be a text
+ name, such as `le0' or a simple port number, such as `1',
+ depending on the interface naming syntax of the device. If
+ several entries in the ifTable together represent a single
+ interface as named by the device, then each will have the
+ same value of ifName. Note that for an agent which responds
+ to SNMP queries concerning an interface on some other
+ (proxied) device, then the value of ifName for such an
+ interface is the proxied device's local name for it.
+
+ If there is no local name, or this object is otherwise not
+ applicable, then this object contains a zero-length string."
+ ::= { ifXEntry 1 }
+
+ifInMulticastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were addressed to a multicast
+ address at this sub-layer. For a MAC layer protocol, this
+ includes both Group and Functional addresses.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 2 }
+
+ifInBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were addressed to a broadcast
+ address at this sub-layer.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 3 }
+
+ifOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were addressed to a
+ multicast address at this sub-layer, including those that
+ were discarded or not sent. For a MAC layer protocol, this
+ includes both Group and Functional addresses.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 4 }
+
+ifOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were addressed to a
+ broadcast address at this sub-layer, including those that
+ were discarded or not sent.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 5 }
+
+--
+-- High Capacity Counter objects. These objects are all
+-- 64 bit versions of the "basic" ifTable counters. These
+-- objects all have the same basic semantics as their 32-bit
+-- counterparts, however, their syntax has been extended
+-- to 64 bits.
+--
+
+ifHCInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received on the interface,
+ including framing characters. This object is a 64-bit
+ version of ifInOctets.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 6 }
+
+ifHCInUcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were not addressed to a multicast
+ or broadcast address at this sub-layer. This object is a
+ 64-bit version of ifInUcastPkts.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 7 }
+
+ifHCInMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were addressed to a multicast
+ address at this sub-layer. For a MAC layer protocol, this
+ includes both Group and Functional addresses. This object
+ is a 64-bit version of ifInMulticastPkts.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 8 }
+
+ifHCInBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, delivered by this sub-layer to a
+ higher (sub-)layer, which were addressed to a broadcast
+ address at this sub-layer. This object is a 64-bit version
+ of ifInBroadcastPkts.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 9 }
+
+ifHCOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets transmitted out of the
+ interface, including framing characters. This object is a
+ 64-bit version of ifOutOctets.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 10 }
+
+ifHCOutUcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were not addressed to a
+ multicast or broadcast address at this sub-layer, including
+ those that were discarded or not sent. This object is a
+ 64-bit version of ifOutUcastPkts.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 11 }
+
+ifHCOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were addressed to a
+ multicast address at this sub-layer, including those that
+ were discarded or not sent. For a MAC layer protocol, this
+ includes both Group and Functional addresses. This object
+ is a 64-bit version of ifOutMulticastPkts.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 12 }
+
+ifHCOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets that higher-level protocols
+ requested be transmitted, and which were addressed to a
+ broadcast address at this sub-layer, including those that
+ were discarded or not sent. This object is a 64-bit version
+ of ifOutBroadcastPkts.
+
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ifCounterDiscontinuityTime."
+ ::= { ifXEntry 13 }
+
+ifLinkUpDownTrapEnable OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether linkUp/linkDown traps should be generated
+ for this interface.
+
+ By default, this object should have the value enabled(1) for
+ interfaces which do not operate on 'top' of any other
+ interface (as defined in the ifStackTable), and disabled(2)
+ otherwise."
+ ::= { ifXEntry 14 }
+
+ifHighSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's current bandwidth in units
+ of 1,000,000 bits per second. If this object reports a
+ value of `n' then the speed of the interface is somewhere in
+ the range of `n-500,000' to `n+499,999'. For interfaces
+ which do not vary in bandwidth or for those where no
+ accurate estimation can be made, this object should contain
+ the nominal bandwidth. For a sub-layer which has no concept
+ of bandwidth, this object should be zero."
+ ::= { ifXEntry 15 }
+
+ifPromiscuousMode OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object has a value of false(2) if this interface only
+ accepts packets/frames that are addressed to this station.
+ This object has a value of true(1) when the station accepts
+ all packets/frames transmitted on the media. The value
+ true(1) is only legal on certain types of media. If legal,
+ setting this object to a value of true(1) may require the
+ interface to be reset before becoming effective.
+
+ The value of ifPromiscuousMode does not affect the reception
+ of broadcast and multicast packets/frames by the interface."
+ ::= { ifXEntry 16 }
+
+ifConnectorPresent OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object has the value 'true(1)' if the interface
+ sublayer has a physical connector and the value 'false(2)'
+ otherwise."
+ ::= { ifXEntry 17 }
+
+ifAlias OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is an 'alias' name for the interface as
+ specified by a network manager, and provides a non-volatile
+ 'handle' for the interface.
+
+ On the first instantiation of an interface, the value of
+ ifAlias associated with that interface is the zero-length
+ string. As and when a value is written into an instance of
+ ifAlias through a network management set operation, then the
+ agent must retain the supplied value in the ifAlias instance
+ associated with the same interface for as long as that
+ interface remains instantiated, including across all re-
+ initializations/reboots of the network management system,
+ including those which result in a change of the interface's
+ ifIndex value.
+
+ An example of the value which a network manager might store
+ in this object for a WAN interface is the (Telco's) circuit
+ number/identifier of the interface.
+
+ Some agents may support write-access only for interfaces
+ having particular values of ifType. An agent which supports
+ write access to this object is required to keep the value in
+ non-volatile storage, but it may limit the length of new
+ values depending on how much storage is already occupied by
+ the current values for other interfaces."
+ ::= { ifXEntry 18 }
+
+ifCounterDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime on the most recent occasion at which
+ any one or more of this interface's counters suffered a
+ discontinuity. The relevant counters are the specific
+ instances associated with this interface of any Counter32 or
+
+ Counter64 object contained in the ifTable or ifXTable. If
+ no such discontinuities have occurred since the last re-
+ initialization of the local management subsystem, then this
+ object contains a zero value."
+ ::= { ifXEntry 19 }
+
+-- The Interface Stack Group
+--
+-- Implementation of this group is optional, but strongly recommended
+-- for all systems
+--
+
+ifStackTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfStackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table containing information on the relationships
+ between the multiple sub-layers of network interfaces. In
+ particular, it contains information on which sub-layers run
+ 'on top of' which other sub-layers, where each sub-layer
+ corresponds to a conceptual row in the ifTable. For
+ example, when the sub-layer with ifIndex value x runs over
+ the sub-layer with ifIndex value y, then this table
+ contains:
+
+ ifStackStatus.x.y=active
+
+ For each ifIndex value, I, which identifies an active
+ interface, there are always at least two instantiated rows
+ in this table associated with I. For one of these rows, I
+ is the value of ifStackHigherLayer; for the other, I is the
+ value of ifStackLowerLayer. (If I is not involved in
+ multiplexing, then these are the only two rows associated
+ with I.)
+
+ For example, two rows exist even for an interface which has
+ no others stacked on top or below it:
+
+ ifStackStatus.0.x=active
+ ifStackStatus.x.0=active "
+ ::= { ifMIBObjects 2 }
+
+ifStackEntry OBJECT-TYPE
+ SYNTAX IfStackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information on a particular relationship between two sub-
+ layers, specifying that one sub-layer runs on 'top' of the
+ other sub-layer. Each sub-layer corresponds to a conceptual
+ row in the ifTable."
+ INDEX { ifStackHigherLayer, ifStackLowerLayer }
+ ::= { ifStackTable 1 }
+
+IfStackEntry ::=
+ SEQUENCE {
+ ifStackHigherLayer InterfaceIndexOrZero,
+ ifStackLowerLayer InterfaceIndexOrZero,
+ ifStackStatus RowStatus
+ }
+
+ifStackHigherLayer OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The value of ifIndex corresponding to the higher sub-layer
+ of the relationship, i.e., the sub-layer which runs on 'top'
+ of the sub-layer identified by the corresponding instance of
+ ifStackLowerLayer. If there is no higher sub-layer (below
+ the internetwork layer), then this object has the value 0."
+ ::= { ifStackEntry 1 }
+
+ifStackLowerLayer OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The value of ifIndex corresponding to the lower sub-layer
+ of the relationship, i.e., the sub-layer which runs 'below'
+ the sub-layer identified by the corresponding instance of
+ ifStackHigherLayer. If there is no lower sub-layer, then
+ this object has the value 0."
+ ::= { ifStackEntry 2 }
+
+ifStackStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of the relationship between two sub-layers.
+
+ Changing the value of this object from 'active' to
+ 'notInService' or 'destroy' will likely have consequences up
+ and down the interface stack. Thus, write access to this
+ object is likely to be inappropriate for some types of
+ interfaces, and many implementations will choose not to
+ support write-access for any type of interface."
+ ::= { ifStackEntry 3 }
+
+ifStackLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time of the last change of
+ the (whole) interface stack. A change of the interface
+ stack is defined to be any creation, deletion, or change in
+ value of any instance of ifStackStatus. If the interface
+ stack has been unchanged since the last re-initialization of
+ the local network management subsystem, then this object
+ contains a zero value."
+ ::= { ifMIBObjects 6 }
+
+-- Generic Receive Address Table
+--
+-- This group of objects is mandatory for all types of
+-- interfaces which can receive packets/frames addressed to
+-- more than one address.
+--
+-- This table replaces the ifExtnsRcvAddr table. The main
+-- difference is that this table makes use of the RowStatus
+-- textual convention, while ifExtnsRcvAddr did not.
+
+ifRcvAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfRcvAddressEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains an entry for each address (broadcast,
+ multicast, or uni-cast) for which the system will receive
+ packets/frames on a particular interface, except as follows:
+
+ - for an interface operating in promiscuous mode, entries
+ are only required for those addresses for which the system
+ would receive frames were it not operating in promiscuous
+ mode.
+
+ - for 802.5 functional addresses, only one entry is
+ required, for the address which has the functional address
+ bit ANDed with the bit mask of all functional addresses for
+ which the interface will accept frames.
+
+ A system is normally able to use any unicast address which
+ corresponds to an entry in this table as a source address."
+ ::= { ifMIBObjects 4 }
+
+ifRcvAddressEntry OBJECT-TYPE
+ SYNTAX IfRcvAddressEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of objects identifying an address for which the
+ system will accept packets/frames on the particular
+ interface identified by the index value ifIndex."
+ INDEX { ifIndex, ifRcvAddressAddress }
+ ::= { ifRcvAddressTable 1 }
+
+IfRcvAddressEntry ::=
+ SEQUENCE {
+ ifRcvAddressAddress PhysAddress,
+ ifRcvAddressStatus RowStatus,
+ ifRcvAddressType INTEGER
+ }
+
+ifRcvAddressAddress OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An address for which the system will accept packets/frames
+ on this entry's interface."
+ ::= { ifRcvAddressEntry 1 }
+
+ifRcvAddressStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to create and delete rows in the
+ ifRcvAddressTable."
+ ::= { ifRcvAddressEntry 2 }
+
+ifRcvAddressType OBJECT-TYPE
+ SYNTAX INTEGER {
+
+ other(1),
+ volatile(2),
+ nonVolatile(3)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object has the value nonVolatile(3) for those entries
+ in the table which are valid and will not be deleted by the
+ next restart of the managed system. Entries having the
+ value volatile(2) are valid and exist, but have not been
+ saved, so that will not exist after the next restart of the
+ managed system. Entries having the value other(1) are valid
+ and exist but are not classified as to whether they will
+ continue to exist after the next restart."
+ DEFVAL { volatile }
+ ::= { ifRcvAddressEntry 3 }
+
+-- definition of interface-related traps.
+
+linkDown NOTIFICATION-TYPE
+ OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
+ STATUS current
+ DESCRIPTION
+ "A linkDown trap signifies that the SNMP entity, acting in
+ an agent role, has detected that the ifOperStatus object for
+ one of its communication links is about to enter the down
+ state from some other state (but not from the notPresent
+ state). This other state is indicated by the included value
+ of ifOperStatus."
+ ::= { snmpTraps 3 }
+
+linkUp NOTIFICATION-TYPE
+ OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
+ STATUS current
+ DESCRIPTION
+ "A linkUp trap signifies that the SNMP entity, acting in an
+ agent role, has detected that the ifOperStatus object for
+ one of its communication links left the down state and
+ transitioned into some other state (but not into the
+ notPresent state). This other state is indicated by the
+ included value of ifOperStatus."
+ ::= { snmpTraps 4 }
+
+-- conformance information
+
+ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 }
+
+ifGroups OBJECT IDENTIFIER ::= { ifConformance 1 }
+ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 }
+
+-- compliance statements
+
+ifCompliance3 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities which have
+ network interfaces."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { ifGeneralInformationGroup,
+ linkUpDownNotificationsGroup }
+
+-- The groups:
+-- ifFixedLengthGroup
+-- ifHCFixedLengthGroup
+-- ifPacketGroup
+-- ifHCPacketGroup
+-- ifVHCPacketGroup
+-- are mutually exclusive; at most one of these groups is implemented
+-- for a particular interface. When any of these groups is implemented
+-- for a particular interface, then ifCounterDiscontinuityGroup must
+-- also be implemented for that interface.
+
+ GROUP ifFixedLengthGroup
+ DESCRIPTION
+ "This group is mandatory for those network interfaces which
+ are character-oriented or transmit data in fixed-length
+ transmission units, and for which the value of the
+ corresponding instance of ifSpeed is less than or equal to
+ 20,000,000 bits/second."
+
+ GROUP ifHCFixedLengthGroup
+ DESCRIPTION
+ "This group is mandatory for those network interfaces which
+ are character-oriented or transmit data in fixed-length
+ transmission units, and for which the value of the
+ corresponding instance of ifSpeed is greater than 20,000,000
+ bits/second."
+
+ GROUP ifPacketGroup
+ DESCRIPTION
+ "This group is mandatory for those network interfaces which
+ are packet-oriented, and for which the value of the
+ corresponding instance of ifSpeed is less than or equal to
+ 20,000,000 bits/second."
+
+ GROUP ifHCPacketGroup
+ DESCRIPTION
+ "This group is mandatory only for those network interfaces
+ which are packet-oriented and for which the value of the
+ corresponding instance of ifSpeed is greater than 20,000,000
+ bits/second but less than or equal to 650,000,000
+ bits/second."
+
+ GROUP ifVHCPacketGroup
+ DESCRIPTION
+ "This group is mandatory only for those network interfaces
+ which are packet-oriented and for which the value of the
+ corresponding instance of ifSpeed is greater than
+ 650,000,000 bits/second."
+
+ GROUP ifCounterDiscontinuityGroup
+ DESCRIPTION
+ "This group is mandatory for those network interfaces that
+ are required to maintain counters (i.e., those for which one
+ of the ifFixedLengthGroup, ifHCFixedLengthGroup,
+ ifPacketGroup, ifHCPacketGroup, or ifVHCPacketGroup is
+ mandatory)."
+
+ GROUP ifRcvAddressGroup
+ DESCRIPTION
+ "The applicability of this group MUST be defined by the
+ media-specific MIBs. Media-specific MIBs must define the
+ exact meaning, use, and semantics of the addresses in this
+ group."
+
+ OBJECT ifLinkUpDownTrapEnable
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT ifPromiscuousMode
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT ifAdminStatus
+ SYNTAX INTEGER { up(1), down(2) }
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, nor is support for the value
+ testing(3)."
+
+ OBJECT ifAlias
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { ifCompliances 3 }
+
+-- units of conformance
+
+ifGeneralInformationGroup OBJECT-GROUP
+ OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress,
+ ifAdminStatus, ifOperStatus, ifLastChange,
+ ifLinkUpDownTrapEnable, ifConnectorPresent,
+ ifHighSpeed, ifName, ifNumber, ifAlias,
+ ifTableLastChange }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information applicable to
+ all network interfaces."
+ ::= { ifGroups 10 }
+
+-- the following five groups are mutually exclusive; at most
+-- one of these groups is implemented for any interface
+
+ifFixedLengthGroup OBJECT-GROUP
+ OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
+ ifInErrors, ifOutErrors }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information specific to
+ non-high speed (non-high speed interfaces transmit and
+ receive at speeds less than or equal to 20,000,000
+ bits/second) character-oriented or fixed-length-transmission
+ network interfaces."
+ ::= { ifGroups 2 }
+
+ifHCFixedLengthGroup OBJECT-GROUP
+ OBJECTS { ifHCInOctets, ifHCOutOctets,
+ ifInOctets, ifOutOctets, ifInUnknownProtos,
+ ifInErrors, ifOutErrors }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information specific to
+ high speed (greater than 20,000,000 bits/second) character-
+ oriented or fixed-length-transmission network interfaces."
+ ::= { ifGroups 3 }
+
+ifPacketGroup OBJECT-GROUP
+ OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
+ ifInErrors, ifOutErrors,
+ ifMtu, ifInUcastPkts, ifInMulticastPkts,
+ ifInBroadcastPkts, ifInDiscards,
+ ifOutUcastPkts, ifOutMulticastPkts,
+ ifOutBroadcastPkts, ifOutDiscards,
+ ifPromiscuousMode }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information specific to
+ non-high speed (non-high speed interfaces transmit and
+ receive at speeds less than or equal to 20,000,000
+ bits/second) packet-oriented network interfaces."
+ ::= { ifGroups 4 }
+
+ifHCPacketGroup OBJECT-GROUP
+ OBJECTS { ifHCInOctets, ifHCOutOctets,
+ ifInOctets, ifOutOctets, ifInUnknownProtos,
+ ifInErrors, ifOutErrors,
+ ifMtu, ifInUcastPkts, ifInMulticastPkts,
+ ifInBroadcastPkts, ifInDiscards,
+ ifOutUcastPkts, ifOutMulticastPkts,
+ ifOutBroadcastPkts, ifOutDiscards,
+ ifPromiscuousMode }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information specific to
+ high speed (greater than 20,000,000 bits/second but less
+ than or equal to 650,000,000 bits/second) packet-oriented
+ network interfaces."
+ ::= { ifGroups 5 }
+
+ifVHCPacketGroup OBJECT-GROUP
+ OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts,
+ ifHCInBroadcastPkts, ifHCOutUcastPkts,
+ ifHCOutMulticastPkts, ifHCOutBroadcastPkts,
+ ifHCInOctets, ifHCOutOctets,
+ ifInOctets, ifOutOctets, ifInUnknownProtos,
+ ifInErrors, ifOutErrors,
+ ifMtu, ifInUcastPkts, ifInMulticastPkts,
+ ifInBroadcastPkts, ifInDiscards,
+ ifOutUcastPkts, ifOutMulticastPkts,
+ ifOutBroadcastPkts, ifOutDiscards,
+ ifPromiscuousMode }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information specific to
+ higher speed (greater than 650,000,000 bits/second) packet-
+ oriented network interfaces."
+ ::= { ifGroups 6 }
+
+ifRcvAddressGroup OBJECT-GROUP
+ OBJECTS { ifRcvAddressStatus, ifRcvAddressType }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information on the
+ multiple addresses which an interface receives."
+ ::= { ifGroups 7 }
+
+ifStackGroup2 OBJECT-GROUP
+ OBJECTS { ifStackStatus, ifStackLastChange }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information on the
+ layering of MIB-II interfaces."
+ ::= { ifGroups 11 }
+
+ifCounterDiscontinuityGroup OBJECT-GROUP
+ OBJECTS { ifCounterDiscontinuityTime }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information specific to
+ interface counter discontinuities."
+ ::= { ifGroups 13 }
+
+linkUpDownNotificationsGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { linkUp, linkDown }
+ STATUS current
+ DESCRIPTION
+ "The notifications which indicate specific changes in the
+ value of ifOperStatus."
+ ::= { ifGroups 14 }
+
+-- Deprecated Definitions - Objects
+
+--
+-- The Interface Test Table
+--
+-- This group of objects is optional. However, a media-specific
+
+-- MIB may make implementation of this group mandatory.
+--
+-- This table replaces the ifExtnsTestTable
+--
+
+ifTestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfTestEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "This table contains one entry per interface. It defines
+ objects which allow a network manager to instruct an agent
+ to test an interface for various faults. Tests for an
+ interface are defined in the media-specific MIB for that
+ interface. After invoking a test, the object ifTestResult
+ can be read to determine the outcome. If an agent can not
+ perform the test, ifTestResult is set to so indicate. The
+ object ifTestCode can be used to provide further test-
+ specific or interface-specific (or even enterprise-specific)
+ information concerning the outcome of the test. Only one
+ test can be in progress on each interface at any one time.
+ If one test is in progress when another test is invoked, the
+ second test is rejected. Some agents may reject a test when
+ a prior test is active on another interface.
+
+ Before starting a test, a manager-station must first obtain
+ 'ownership' of the entry in the ifTestTable for the
+ interface to be tested. This is accomplished with the
+ ifTestId and ifTestStatus objects as follows:
+
+ try_again:
+ get (ifTestId, ifTestStatus)
+ while (ifTestStatus != notInUse)
+ /*
+ * Loop while a test is running or some other
+ * manager is configuring a test.
+ */
+ short delay
+ get (ifTestId, ifTestStatus)
+ }
+
+ /*
+ * Is not being used right now -- let's compete
+ * to see who gets it.
+ */
+ lock_value = ifTestId
+
+ if ( set(ifTestId = lock_value, ifTestStatus = inUse,
+ ifTestOwner = 'my-IP-address') == FAILURE)
+ /*
+ * Another manager got the ifTestEntry -- go
+ * try again
+ */
+ goto try_again;
+
+ /*
+ * I have the lock
+ */
+ set up any test parameters.
+
+ /*
+ * This starts the test
+ */
+ set(ifTestType = test_to_run);
+
+ wait for test completion by polling ifTestResult
+
+ when test completes, agent sets ifTestResult
+ agent also sets ifTestStatus = 'notInUse'
+
+ retrieve any additional test results, and ifTestId
+
+ if (ifTestId == lock_value+1) results are valid
+
+ A manager station first retrieves the value of the
+ appropriate ifTestId and ifTestStatus objects, periodically
+ repeating the retrieval if necessary, until the value of
+ ifTestStatus is 'notInUse'. The manager station then tries
+ to set the same ifTestId object to the value it just
+ retrieved, the same ifTestStatus object to 'inUse', and the
+ corresponding ifTestOwner object to a value indicating
+ itself. If the set operation succeeds then the manager has
+ obtained ownership of the ifTestEntry, and the value of the
+ ifTestId object is incremented by the agent (per the
+ semantics of TestAndIncr). Failure of the set operation
+ indicates that some other manager has obtained ownership of
+ the ifTestEntry.
+
+ Once ownership is obtained, any test parameters can be
+ setup, and then the test is initiated by setting ifTestType.
+ On completion of the test, the agent sets ifTestStatus to
+ 'notInUse'. Once this occurs, the manager can retrieve the
+ results. In the (rare) event that the invocation of tests
+ by two network managers were to overlap, then there would be
+ a possibility that the first test's results might be
+ overwritten by the second test's results prior to the first
+
+ results being read. This unlikely circumstance can be
+ detected by a network manager retrieving ifTestId at the
+ same time as retrieving the test results, and ensuring that
+ the results are for the desired request.
+
+ If ifTestType is not set within an abnormally long period of
+ time after ownership is obtained, the agent should time-out
+ the manager, and reset the value of the ifTestStatus object
+ back to 'notInUse'. It is suggested that this time-out
+ period be 5 minutes.
+
+ In general, a management station must not retransmit a
+ request to invoke a test for which it does not receive a
+ response; instead, it properly inspects an agent's MIB to
+ determine if the invocation was successful. Only if the
+ invocation was unsuccessful, is the invocation request
+ retransmitted.
+
+ Some tests may require the interface to be taken off-line in
+ order to execute them, or may even require the agent to
+ reboot after completion of the test. In these
+ circumstances, communication with the management station
+ invoking the test may be lost until after completion of the
+ test. An agent is not required to support such tests.
+ However, if such tests are supported, then the agent should
+ make every effort to transmit a response to the request
+ which invoked the test prior to losing communication. When
+ the agent is restored to normal service, the results of the
+ test are properly made available in the appropriate objects.
+ Note that this requires that the ifIndex value assigned to
+ an interface must be unchanged even if the test causes a
+ reboot. An agent must reject any test for which it cannot,
+ perhaps due to resource constraints, make available at least
+ the minimum amount of information after that test
+ completes."
+ ::= { ifMIBObjects 3 }
+
+ifTestEntry OBJECT-TYPE
+ SYNTAX IfTestEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "An entry containing objects for invoking tests on an
+ interface."
+ AUGMENTS { ifEntry }
+ ::= { ifTestTable 1 }
+
+IfTestEntry ::=
+
+ SEQUENCE {
+ ifTestId TestAndIncr,
+ ifTestStatus INTEGER,
+ ifTestType AutonomousType,
+ ifTestResult INTEGER,
+ ifTestCode OBJECT IDENTIFIER,
+ ifTestOwner OwnerString
+ }
+
+ifTestId OBJECT-TYPE
+ SYNTAX TestAndIncr
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "This object identifies the current invocation of the
+ interface's test."
+ ::= { ifTestEntry 1 }
+
+ifTestStatus OBJECT-TYPE
+ SYNTAX INTEGER { notInUse(1), inUse(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "This object indicates whether or not some manager currently
+ has the necessary 'ownership' required to invoke a test on
+ this interface. A write to this object is only successful
+ when it changes its value from 'notInUse(1)' to 'inUse(2)'.
+ After completion of a test, the agent resets the value back
+ to 'notInUse(1)'."
+ ::= { ifTestEntry 2 }
+
+ifTestType OBJECT-TYPE
+ SYNTAX AutonomousType
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "A control variable used to start and stop operator-
+ initiated interface tests. Most OBJECT IDENTIFIER values
+ assigned to tests are defined elsewhere, in association with
+ specific types of interface. However, this document assigns
+ a value for a full-duplex loopback test, and defines the
+ special meanings of the subject identifier:
+
+ noTest OBJECT IDENTIFIER ::= { 0 0 }
+
+ When the value noTest is written to this object, no action
+ is taken unless a test is in progress, in which case the
+ test is aborted. Writing any other value to this object is
+
+ only valid when no test is currently in progress, in which
+ case the indicated test is initiated.
+
+ When read, this object always returns the most recent value
+ that ifTestType was set to. If it has not been set since
+ the last initialization of the network management subsystem
+ on the agent, a value of noTest is returned."
+ ::= { ifTestEntry 3 }
+
+ifTestResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1), -- no test yet requested
+ success(2),
+ inProgress(3),
+ notSupported(4),
+ unAbleToRun(5), -- due to state of system
+ aborted(6),
+ failed(7)
+ }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object contains the result of the most recently
+ requested test, or the value none(1) if no tests have been
+ requested since the last reset. Note that this facility
+ provides no provision for saving the results of one test
+ when starting another, as could be required if used by
+ multiple managers concurrently."
+ ::= { ifTestEntry 4 }
+
+ifTestCode OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "This object contains a code which contains more specific
+ information on the test result, for example an error-code
+ after a failed test. Error codes and other values this
+ object may take are specific to the type of interface and/or
+ test. The value may have the semantics of either the
+ AutonomousType or InstancePointer textual conventions as
+ defined in RFC 2579. The identifier:
+
+ testCodeUnknown OBJECT IDENTIFIER ::= { 0 0 }
+
+ is defined for use if no additional result code is
+ available."
+ ::= { ifTestEntry 5 }
+
+ifTestOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "The entity which currently has the 'ownership' required to
+ invoke a test on this interface."
+ ::= { ifTestEntry 6 }
+
+-- Deprecated Definitions - Groups
+
+ifGeneralGroup OBJECT-GROUP
+ OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress,
+ ifAdminStatus, ifOperStatus, ifLastChange,
+ ifLinkUpDownTrapEnable, ifConnectorPresent,
+ ifHighSpeed, ifName }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of objects deprecated in favour of
+ ifGeneralInformationGroup."
+ ::= { ifGroups 1 }
+
+ifTestGroup OBJECT-GROUP
+ OBJECTS { ifTestId, ifTestStatus, ifTestType,
+ ifTestResult, ifTestCode, ifTestOwner }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of objects providing the ability to invoke
+ tests on an interface."
+ ::= { ifGroups 8 }
+
+ifStackGroup OBJECT-GROUP
+ OBJECTS { ifStackStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "The previous collection of objects providing information on
+ the layering of MIB-II interfaces."
+ ::= { ifGroups 9 }
+
+ifOldObjectsGroup OBJECT-GROUP
+ OBJECTS { ifInNUcastPkts, ifOutNUcastPkts,
+ ifOutQLen, ifSpecific }
+ STATUS deprecated
+ DESCRIPTION
+ "The collection of objects deprecated from the original MIB-
+ II interfaces group."
+ ::= { ifGroups 12 }
+
+-- Deprecated Definitions - Compliance
+
+ifCompliance MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "A compliance statement defined in a previous version of
+ this MIB module, for SNMP entities which have network
+ interfaces."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup }
+
+ GROUP ifFixedLengthGroup
+ DESCRIPTION
+ "This group is mandatory for all network interfaces which
+ are character-oriented or transmit data in fixed-length
+ transmission units."
+
+ GROUP ifHCFixedLengthGroup
+ DESCRIPTION
+ "This group is mandatory only for those network interfaces
+ which are character-oriented or transmit data in fixed-
+ length transmission units, and for which the value of the
+ corresponding instance of ifSpeed is greater than 20,000,000
+ bits/second."
+
+ GROUP ifPacketGroup
+ DESCRIPTION
+ "This group is mandatory for all network interfaces which
+ are packet-oriented."
+
+ GROUP ifHCPacketGroup
+ DESCRIPTION
+ "This group is mandatory only for those network interfaces
+ which are packet-oriented and for which the value of the
+ corresponding instance of ifSpeed is greater than
+ 650,000,000 bits/second."
+
+ GROUP ifTestGroup
+ DESCRIPTION
+ "This group is optional. Media-specific MIBs which require
+ interface tests are strongly encouraged to use this group
+ for invoking tests and reporting results. A medium specific
+ MIB which has mandatory tests may make implementation of
+
+ this group mandatory."
+
+ GROUP ifRcvAddressGroup
+ DESCRIPTION
+ "The applicability of this group MUST be defined by the
+ media-specific MIBs. Media-specific MIBs must define the
+ exact meaning, use, and semantics of the addresses in this
+ group."
+
+ OBJECT ifLinkUpDownTrapEnable
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT ifPromiscuousMode
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT ifStackStatus
+ SYNTAX INTEGER { active(1) } -- subset of RowStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, and only one of the six
+ enumerated values for the RowStatus textual convention need
+ be supported, specifically: active(1)."
+
+ OBJECT ifAdminStatus
+ SYNTAX INTEGER { up(1), down(2) }
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, nor is support for the value
+ testing(3)."
+ ::= { ifCompliances 1 }
+
+ifCompliance2 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "A compliance statement defined in a previous version of
+ this MIB module, for SNMP entities which have network
+ interfaces."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { ifGeneralInformationGroup, ifStackGroup2,
+ ifCounterDiscontinuityGroup }
+
+ GROUP ifFixedLengthGroup
+ DESCRIPTION
+ "This group is mandatory for all network interfaces which
+ are character-oriented or transmit data in fixed-length
+ transmission units."
+
+ GROUP ifHCFixedLengthGroup
+ DESCRIPTION
+ "This group is mandatory only for those network interfaces
+ which are character-oriented or transmit data in fixed-
+ length transmission units, and for which the value of the
+ corresponding instance of ifSpeed is greater than 20,000,000
+ bits/second."
+
+ GROUP ifPacketGroup
+ DESCRIPTION
+ "This group is mandatory for all network interfaces which
+ are packet-oriented."
+
+ GROUP ifHCPacketGroup
+ DESCRIPTION
+ "This group is mandatory only for those network interfaces
+ which are packet-oriented and for which the value of the
+ corresponding instance of ifSpeed is greater than
+ 650,000,000 bits/second."
+
+ GROUP ifRcvAddressGroup
+ DESCRIPTION
+ "The applicability of this group MUST be defined by the
+ media-specific MIBs. Media-specific MIBs must define the
+ exact meaning, use, and semantics of the addresses in this
+ group."
+
+ OBJECT ifLinkUpDownTrapEnable
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT ifPromiscuousMode
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT ifStackStatus
+ SYNTAX INTEGER { active(1) } -- subset of RowStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, and only one of the six
+ enumerated values for the RowStatus textual convention need
+ be supported, specifically: active(1)."
+
+ OBJECT ifAdminStatus
+ SYNTAX INTEGER { up(1), down(2) }
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, nor is support for the value
+ testing(3)."
+
+ OBJECT ifAlias
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { ifCompliances 2 }
+
+END
diff --git a/NEZHA/config_file/SNMPv2-MIB.txt b/NEZHA/config_file/SNMPv2-MIB.txt
new file mode 100644
index 0000000..8c82830
--- /dev/null
+++ b/NEZHA/config_file/SNMPv2-MIB.txt
@@ -0,0 +1,854 @@
+SNMPv2-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ TimeTicks, Counter32, snmpModules, mib-2
+ FROM SNMPv2-SMI
+ DisplayString, TestAndIncr, TimeStamp
+
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF;
+
+snmpMIB MODULE-IDENTITY
+ LAST-UPDATED "200210160000Z"
+ ORGANIZATION "IETF SNMPv3 Working Group"
+ CONTACT-INFO
+ "WG-EMail: [email protected]
+ Subscribe: [email protected]
+
+ Co-Chair: Russ Mundy
+ Network Associates Laboratories
+ postal: 15204 Omega Drive, Suite 300
+ Rockville, MD 20850-4601
+ USA
+ phone: +1 301 947-7107
+
+ Co-Chair: David Harrington
+ Enterasys Networks
+ postal: 35 Industrial Way
+ P. O. Box 5005
+ Rochester, NH 03866-5005
+ USA
+ phone: +1 603 337-2614
+
+ Editor: Randy Presuhn
+ BMC Software, Inc.
+ postal: 2141 North First Street
+ San Jose, CA 95131
+ USA
+ phone: +1 408 546-1006"
+ DESCRIPTION
+ "The MIB module for SNMP entities.
+
+ Copyright (C) The Internet Society (2002). This
+ version of this MIB module is part of RFC 3418;
+ see the RFC itself for full legal notices.
+ "
+ REVISION "200210160000Z"
+ DESCRIPTION
+ "This revision of this MIB module was published as
+ RFC 3418."
+ REVISION "199511090000Z"
+ DESCRIPTION
+ "This revision of this MIB module was published as
+ RFC 1907."
+ REVISION "199304010000Z"
+ DESCRIPTION
+ "The initial revision of this MIB module was published
+ as RFC 1450."
+ ::= { snmpModules 1 }
+
+snmpMIBObjects OBJECT IDENTIFIER ::= { snmpMIB 1 }
+
+-- ::= { snmpMIBObjects 1 } this OID is obsolete
+-- ::= { snmpMIBObjects 2 } this OID is obsolete
+-- ::= { snmpMIBObjects 3 } this OID is obsolete
+
+-- the System group
+--
+-- a collection of objects common to all managed systems.
+
+system OBJECT IDENTIFIER ::= { mib-2 1 }
+
+sysDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual description of the entity. This value should
+ include the full name and version identification of
+ the system's hardware type, software operating-system,
+ and networking software."
+ ::= { system 1 }
+
+sysObjectID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor's authoritative identification of the
+ network management subsystem contained in the entity.
+ This value is allocated within the SMI enterprises
+ subtree (1.3.6.1.4.1) and provides an easy and
+ unambiguous means for determining `what kind of box' is
+ being managed. For example, if vendor `Flintstones,
+ Inc.' was assigned the subtree 1.3.6.1.4.1.424242,
+ it could assign the identifier 1.3.6.1.4.1.424242.1.1
+ to its `Fred Router'."
+ ::= { system 2 }
+
+sysUpTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time (in hundredths of a second) since the
+ network management portion of the system was last
+ re-initialized."
+ ::= { system 3 }
+
+sysContact OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The textual identification of the contact person for
+ this managed node, together with information on how
+ to contact this person. If no contact information is
+ known, the value is the zero-length string."
+ ::= { system 4 }
+
+sysName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An administratively-assigned name for this managed
+ node. By convention, this is the node's fully-qualified
+ domain name. If the name is unknown, the value is
+ the zero-length string."
+ ::= { system 5 }
+
+sysLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The physical location of this node (e.g., 'telephone
+ closet, 3rd floor'). If the location is unknown, the
+ value is the zero-length string."
+ ::= { system 6 }
+
+sysServices OBJECT-TYPE
+ SYNTAX INTEGER (0..127)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A value which indicates the set of services that this
+ entity may potentially offer. The value is a sum.
+
+ This sum initially takes the value zero. Then, for
+ each layer, L, in the range 1 through 7, that this node
+ performs transactions for, 2 raised to (L - 1) is added
+ to the sum. For example, a node which performs only
+ routing functions would have a value of 4 (2^(3-1)).
+ In contrast, a node which is a host offering application
+ services would have a value of 72 (2^(4-1) + 2^(7-1)).
+ Note that in the context of the Internet suite of
+ protocols, values should be calculated accordingly:
+
+ layer functionality
+ 1 physical (e.g., repeaters)
+ 2 datalink/subnetwork (e.g., bridges)
+ 3 internet (e.g., supports the IP)
+ 4 end-to-end (e.g., supports the TCP)
+ 7 applications (e.g., supports the SMTP)
+
+ For systems including OSI protocols, layers 5 and 6
+ may also be counted."
+ ::= { system 7 }
+
+-- object resource information
+--
+-- a collection of objects which describe the SNMP entity's
+-- (statically and dynamically configurable) support of
+-- various MIB modules.
+
+sysORLastChange OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time of the most recent
+ change in state or value of any instance of sysORID."
+ ::= { system 8 }
+
+sysORTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SysOREntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The (conceptual) table listing the capabilities of
+ the local SNMP application acting as a command
+ responder with respect to various MIB modules.
+ SNMP entities having dynamically-configurable support
+ of MIB modules will have a dynamically-varying number
+ of conceptual rows."
+ ::= { system 9 }
+
+sysOREntry OBJECT-TYPE
+ SYNTAX SysOREntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) in the sysORTable."
+ INDEX { sysORIndex }
+ ::= { sysORTable 1 }
+
+SysOREntry ::= SEQUENCE {
+ sysORIndex INTEGER,
+ sysORID OBJECT IDENTIFIER,
+ sysORDescr DisplayString,
+ sysORUpTime TimeStamp
+}
+
+sysORIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The auxiliary variable used for identifying instances
+ of the columnar objects in the sysORTable."
+ ::= { sysOREntry 1 }
+
+sysORID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An authoritative identification of a capabilities
+ statement with respect to various MIB modules supported
+ by the local SNMP application acting as a command
+ responder."
+ ::= { sysOREntry 2 }
+
+sysORDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual description of the capabilities identified
+ by the corresponding instance of sysORID."
+ ::= { sysOREntry 3 }
+
+sysORUpTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time this conceptual
+ row was last instantiated."
+ ::= { sysOREntry 4 }
+
+-- the SNMP group
+--
+-- a collection of objects providing basic instrumentation and
+-- control of an SNMP entity.
+
+snmp OBJECT IDENTIFIER ::= { mib-2 11 }
+
+snmpInPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of messages delivered to the SNMP
+ entity from the transport service."
+ ::= { snmp 1 }
+
+snmpInBadVersions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of SNMP messages which were delivered
+ to the SNMP entity and were for an unsupported SNMP
+ version."
+ ::= { snmp 3 }
+
+snmpInBadCommunityNames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of community-based SNMP messages (for
+ example, SNMPv1) delivered to the SNMP entity which
+ used an SNMP community name not known to said entity.
+ Also, implementations which authenticate community-based
+ SNMP messages using check(s) in addition to matching
+ the community name (for example, by also checking
+ whether the message originated from a transport address
+ allowed to use a specified community name) MAY include
+ in this value the number of messages which failed the
+ additional check(s). It is strongly RECOMMENDED that
+
+ the documentation for any security model which is used
+ to authenticate community-based SNMP messages specify
+ the precise conditions that contribute to this value."
+ ::= { snmp 4 }
+
+snmpInBadCommunityUses OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of community-based SNMP messages (for
+ example, SNMPv1) delivered to the SNMP entity which
+ represented an SNMP operation that was not allowed for
+ the SNMP community named in the message. The precise
+ conditions under which this counter is incremented
+ (if at all) depend on how the SNMP entity implements
+ its access control mechanism and how its applications
+ interact with that access control mechanism. It is
+ strongly RECOMMENDED that the documentation for any
+ access control mechanism which is used to control access
+ to and visibility of MIB instrumentation specify the
+ precise conditions that contribute to this value."
+ ::= { snmp 5 }
+
+snmpInASNParseErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of ASN.1 or BER errors encountered by
+ the SNMP entity when decoding received SNMP messages."
+ ::= { snmp 6 }
+
+snmpEnableAuthenTraps OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the SNMP entity is permitted to
+ generate authenticationFailure traps. The value of this
+ object overrides any configuration information; as such,
+ it provides a means whereby all authenticationFailure
+ traps may be disabled.
+
+ Note that it is strongly recommended that this object
+ be stored in non-volatile memory so that it remains
+ constant across re-initializations of the network
+ management system."
+ ::= { snmp 30 }
+
+snmpSilentDrops OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Confirmed Class PDUs (such as
+ GetRequest-PDUs, GetNextRequest-PDUs,
+ GetBulkRequest-PDUs, SetRequest-PDUs, and
+ InformRequest-PDUs) delivered to the SNMP entity which
+ were silently dropped because the size of a reply
+ containing an alternate Response Class PDU (such as a
+ Response-PDU) with an empty variable-bindings field
+ was greater than either a local constraint or the
+ maximum message size associated with the originator of
+ the request."
+ ::= { snmp 31 }
+
+snmpProxyDrops OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Confirmed Class PDUs
+ (such as GetRequest-PDUs, GetNextRequest-PDUs,
+ GetBulkRequest-PDUs, SetRequest-PDUs, and
+ InformRequest-PDUs) delivered to the SNMP entity which
+ were silently dropped because the transmission of
+ the (possibly translated) message to a proxy target
+ failed in a manner (other than a time-out) such that
+ no Response Class PDU (such as a Response-PDU) could
+ be returned."
+ ::= { snmp 32 }
+
+-- information for notifications
+--
+-- a collection of objects which allow the SNMP entity, when
+-- supporting a notification originator application,
+-- to be configured to generate SNMPv2-Trap-PDUs.
+
+snmpTrap OBJECT IDENTIFIER ::= { snmpMIBObjects 4 }
+
+snmpTrapOID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The authoritative identification of the notification
+ currently being sent. This variable occurs as
+ the second varbind in every SNMPv2-Trap-PDU and
+ InformRequest-PDU."
+ ::= { snmpTrap 1 }
+
+-- ::= { snmpTrap 2 } this OID is obsolete
+
+snmpTrapEnterprise OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The authoritative identification of the enterprise
+ associated with the trap currently being sent. When an
+ SNMP proxy agent is mapping an RFC1157 Trap-PDU
+ into a SNMPv2-Trap-PDU, this variable occurs as the
+ last varbind."
+ ::= { snmpTrap 3 }
+
+-- ::= { snmpTrap 4 } this OID is obsolete
+
+-- well-known traps
+
+snmpTraps OBJECT IDENTIFIER ::= { snmpMIBObjects 5 }
+
+coldStart NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A coldStart trap signifies that the SNMP entity,
+ supporting a notification originator application, is
+ reinitializing itself and that its configuration may
+ have been altered."
+ ::= { snmpTraps 1 }
+
+warmStart NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A warmStart trap signifies that the SNMP entity,
+ supporting a notification originator application,
+ is reinitializing itself such that its configuration
+ is unaltered."
+ ::= { snmpTraps 2 }
+
+-- Note the linkDown NOTIFICATION-TYPE ::= { snmpTraps 3 }
+-- and the linkUp NOTIFICATION-TYPE ::= { snmpTraps 4 }
+-- are defined in RFC 2863 [RFC2863]
+
+authenticationFailure NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An authenticationFailure trap signifies that the SNMP
+ entity has received a protocol message that is not
+ properly authenticated. While all implementations
+ of SNMP entities MAY be capable of generating this
+ trap, the snmpEnableAuthenTraps object indicates
+ whether this trap will be generated."
+ ::= { snmpTraps 5 }
+
+-- Note the egpNeighborLoss notification is defined
+-- as { snmpTraps 6 } in RFC 1213
+
+-- the set group
+--
+-- a collection of objects which allow several cooperating
+-- command generator applications to coordinate their use of the
+-- set operation.
+
+snmpSet OBJECT IDENTIFIER ::= { snmpMIBObjects 6 }
+
+snmpSetSerialNo OBJECT-TYPE
+ SYNTAX TestAndIncr
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An advisory lock used to allow several cooperating
+ command generator applications to coordinate their
+ use of the SNMP set operation.
+
+ This object is used for coarse-grain coordination.
+ To achieve fine-grain coordination, one or more similar
+ objects might be defined within each MIB group, as
+ appropriate."
+ ::= { snmpSet 1 }
+
+-- conformance information
+
+snmpMIBConformance
+ OBJECT IDENTIFIER ::= { snmpMIB 2 }
+
+snmpMIBCompliances
+ OBJECT IDENTIFIER ::= { snmpMIBConformance 1 }
+snmpMIBGroups OBJECT IDENTIFIER ::= { snmpMIBConformance 2 }
+
+-- compliance statements
+
+-- ::= { snmpMIBCompliances 1 } this OID is obsolete
+snmpBasicCompliance MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for SNMPv2 entities which
+ implement the SNMPv2 MIB.
+
+ This compliance statement is replaced by
+ snmpBasicComplianceRev2."
+ MODULE -- this module
+ MANDATORY-GROUPS { snmpGroup, snmpSetGroup, systemGroup,
+ snmpBasicNotificationsGroup }
+
+ GROUP snmpCommunityGroup
+ DESCRIPTION
+ "This group is mandatory for SNMPv2 entities which
+ support community-based authentication."
+ ::= { snmpMIBCompliances 2 }
+
+snmpBasicComplianceRev2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities which
+ implement this MIB module."
+ MODULE -- this module
+ MANDATORY-GROUPS { snmpGroup, snmpSetGroup, systemGroup,
+ snmpBasicNotificationsGroup }
+
+ GROUP snmpCommunityGroup
+ DESCRIPTION
+ "This group is mandatory for SNMP entities which
+ support community-based authentication."
+
+ GROUP snmpWarmStartNotificationGroup
+ DESCRIPTION
+ "This group is mandatory for an SNMP entity which
+ supports command responder applications, and is
+ able to reinitialize itself such that its
+ configuration is unaltered."
+ ::= { snmpMIBCompliances 3 }
+
+-- units of conformance
+
+-- ::= { snmpMIBGroups 1 } this OID is obsolete
+-- ::= { snmpMIBGroups 2 } this OID is obsolete
+-- ::= { snmpMIBGroups 3 } this OID is obsolete
+
+-- ::= { snmpMIBGroups 4 } this OID is obsolete
+
+snmpGroup OBJECT-GROUP
+ OBJECTS { snmpInPkts,
+ snmpInBadVersions,
+ snmpInASNParseErrs,
+ snmpSilentDrops,
+ snmpProxyDrops,
+ snmpEnableAuthenTraps }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing basic instrumentation
+ and control of an SNMP entity."
+ ::= { snmpMIBGroups 8 }
+
+snmpCommunityGroup OBJECT-GROUP
+ OBJECTS { snmpInBadCommunityNames,
+ snmpInBadCommunityUses }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing basic instrumentation
+ of a SNMP entity which supports community-based
+ authentication."
+ ::= { snmpMIBGroups 9 }
+
+snmpSetGroup OBJECT-GROUP
+ OBJECTS { snmpSetSerialNo }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects which allow several cooperating
+ command generator applications to coordinate their
+ use of the set operation."
+ ::= { snmpMIBGroups 5 }
+
+systemGroup OBJECT-GROUP
+ OBJECTS { sysDescr, sysObjectID, sysUpTime,
+ sysContact, sysName, sysLocation,
+ sysServices,
+ sysORLastChange, sysORID,
+ sysORUpTime, sysORDescr }
+ STATUS current
+ DESCRIPTION
+ "The system group defines objects which are common to all
+ managed systems."
+ ::= { snmpMIBGroups 6 }
+
+snmpBasicNotificationsGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { coldStart, authenticationFailure }
+ STATUS current
+ DESCRIPTION
+ "The basic notifications implemented by an SNMP entity
+ supporting command responder applications."
+ ::= { snmpMIBGroups 7 }
+
+snmpWarmStartNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { warmStart }
+ STATUS current
+ DESCRIPTION
+ "An additional notification for an SNMP entity supporting
+ command responder applications, if it is able to reinitialize
+ itself such that its configuration is unaltered."
+ ::= { snmpMIBGroups 11 }
+
+snmpNotificationGroup OBJECT-GROUP
+ OBJECTS { snmpTrapOID, snmpTrapEnterprise }
+ STATUS current
+ DESCRIPTION
+ "These objects are required for entities
+ which support notification originator applications."
+ ::= { snmpMIBGroups 12 }
+
+-- definitions in RFC 1213 made obsolete by the inclusion of a
+-- subset of the snmp group in this MIB
+
+snmpOutPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Messages which were
+ passed from the SNMP protocol entity to the
+ transport service."
+ ::= { snmp 2 }
+
+-- { snmp 7 } is not used
+
+snmpInTooBigs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were
+ delivered to the SNMP protocol entity and for
+ which the value of the error-status field was
+ `tooBig'."
+ ::= { snmp 8 }
+
+snmpInNoSuchNames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were
+ delivered to the SNMP protocol entity and for
+ which the value of the error-status field was
+ `noSuchName'."
+ ::= { snmp 9 }
+
+snmpInBadValues OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were
+ delivered to the SNMP protocol entity and for
+ which the value of the error-status field was
+ `badValue'."
+ ::= { snmp 10 }
+
+snmpInReadOnlys OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number valid SNMP PDUs which were delivered
+ to the SNMP protocol entity and for which the value
+ of the error-status field was `readOnly'. It should
+ be noted that it is a protocol error to generate an
+ SNMP PDU which contains the value `readOnly' in the
+ error-status field, as such this object is provided
+ as a means of detecting incorrect implementations of
+ the SNMP."
+ ::= { snmp 11 }
+
+snmpInGenErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were delivered
+ to the SNMP protocol entity and for which the value
+ of the error-status field was `genErr'."
+ ::= { snmp 12 }
+
+snmpInTotalReqVars OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of MIB objects which have been
+ retrieved successfully by the SNMP protocol entity
+ as the result of receiving valid SNMP Get-Request
+ and Get-Next PDUs."
+ ::= { snmp 13 }
+
+snmpInTotalSetVars OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of MIB objects which have been
+ altered successfully by the SNMP protocol entity as
+ the result of receiving valid SNMP Set-Request PDUs."
+ ::= { snmp 14 }
+
+snmpInGetRequests OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Get-Request PDUs which
+ have been accepted and processed by the SNMP
+ protocol entity."
+ ::= { snmp 15 }
+
+snmpInGetNexts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Get-Next PDUs which have been
+ accepted and processed by the SNMP protocol entity."
+ ::= { snmp 16 }
+
+snmpInSetRequests OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Set-Request PDUs which
+ have been accepted and processed by the SNMP protocol
+ entity."
+ ::= { snmp 17 }
+
+snmpInGetResponses OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Get-Response PDUs which
+ have been accepted and processed by the SNMP protocol
+ entity."
+ ::= { snmp 18 }
+
+snmpInTraps OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Trap PDUs which have been
+ accepted and processed by the SNMP protocol entity."
+ ::= { snmp 19 }
+
+snmpOutTooBigs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were generated
+ by the SNMP protocol entity and for which the value
+ of the error-status field was `tooBig.'"
+ ::= { snmp 20 }
+
+snmpOutNoSuchNames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were generated
+ by the SNMP protocol entity and for which the value
+ of the error-status was `noSuchName'."
+ ::= { snmp 21 }
+
+snmpOutBadValues OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were generated
+ by the SNMP protocol entity and for which the value
+ of the error-status field was `badValue'."
+ ::= { snmp 22 }
+
+-- { snmp 23 } is not used
+
+snmpOutGenErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP PDUs which were generated
+ by the SNMP protocol entity and for which the value
+ of the error-status field was `genErr'."
+ ::= { snmp 24 }
+
+snmpOutGetRequests OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Get-Request PDUs which
+ have been generated by the SNMP protocol entity."
+ ::= { snmp 25 }
+
+snmpOutGetNexts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Get-Next PDUs which have
+ been generated by the SNMP protocol entity."
+ ::= { snmp 26 }
+
+snmpOutSetRequests OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Set-Request PDUs which
+ have been generated by the SNMP protocol entity."
+ ::= { snmp 27 }
+
+snmpOutGetResponses OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Get-Response PDUs which
+ have been generated by the SNMP protocol entity."
+ ::= { snmp 28 }
+
+snmpOutTraps OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The total number of SNMP Trap PDUs which have
+ been generated by the SNMP protocol entity."
+ ::= { snmp 29 }
+
+snmpObsoleteGroup OBJECT-GROUP
+ OBJECTS { snmpOutPkts, snmpInTooBigs, snmpInNoSuchNames,
+ snmpInBadValues, snmpInReadOnlys, snmpInGenErrs,
+ snmpInTotalReqVars, snmpInTotalSetVars,
+ snmpInGetRequests, snmpInGetNexts, snmpInSetRequests,
+ snmpInGetResponses, snmpInTraps, snmpOutTooBigs,
+ snmpOutNoSuchNames, snmpOutBadValues,
+ snmpOutGenErrs, snmpOutGetRequests, snmpOutGetNexts,
+ snmpOutSetRequests, snmpOutGetResponses, snmpOutTraps
+ }
+ STATUS obsolete
+ DESCRIPTION
+ "A collection of objects from RFC 1213 made obsolete
+ by this MIB module."
+ ::= { snmpMIBGroups 10 }
+
+END
diff --git a/NEZHA/config_file/asset-model.xlsx b/NEZHA/config_file/asset-model.xlsx
new file mode 100644
index 0000000..7cd2642
--- /dev/null
+++ b/NEZHA/config_file/asset-model.xlsx
Binary files differ
diff --git a/NEZHA/config_file/chart-temp.xlsx b/NEZHA/config_file/chart-temp.xlsx
new file mode 100644
index 0000000..c91989f
--- /dev/null
+++ b/NEZHA/config_file/chart-temp.xlsx
Binary files differ
diff --git a/NEZHA/config_file/module.xlsx b/NEZHA/config_file/module.xlsx
new file mode 100644
index 0000000..f992c5c
--- /dev/null
+++ b/NEZHA/config_file/module.xlsx
Binary files differ